Part Number Hot Search : 
PSMN0 HTL295I 16GJF ZMDC830 MP320 TC4052BF APT20M19 24S150
Product Description
Full Text Search
 

To Download MA1012D12RW Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  key features: ? 10w output power ? 2:1 input voltage range ? compact dip case ? 1,500 vdc i/o isolation ? meets en 55022 ?a? ? single & dual outputs ? wide temperature operation ? industry standard pin-out ma1000rw 2:1 input range, 10w single & dual output dc/dc con vert ers series www.micropowerdirect.com micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com electrical speci? cations speci cations typical @ +25?, nominal input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. input parameter conditions min. typ. max. units input voltage range 12 vdc input 9.0 12.0 18.0 vdc 24 vdc input 18.0 24.0 36.0 48 vdc input 36.0 48.0 75.0 input filter  (pi) filter (meets en 55022 class ?a?) input re? ected ripple current 35.0 ma p - p output parameter conditions min. typ. max. units output voltage accuracy 1.0 % line regulation v in = min to max 0.5 % load regulation, see note 1 single output 0.5 % dual output 1.0 cross regulation, dual output see note 2 5.0 % ripple & noise (20 mhz) see note 3 75 mv p - p output power protection 150 % i out temperature coef? cient 0.02 %/oc output short circuit protection continuous (autorecovery) general parameter conditions min. typ. max. units isolation voltage (input/output) 3 seconds 1,500 vdc isolation voltage (case/input, output) 3 seconds 1,000 isolation resistance 500 vdc 1,000 m isolation capacitance 100 khz/1v 1,000 pf switching frequency 330 khz emi characteristics parameter standard level radiated emissions en 55022 class a conducted emissions, see note 4 en 55022 class a esd en 61000-4-2 criteria b rs en 61000-4-3 criteria a eft, see note 4 en 61000-4-4 criteria b surge, see note 4 en 61000-4-5 criteria b cs en 61000-4-6 criteria a pfmf en 61000-4-8 criteria a environmental parameter conditions min. typ. max. units operating temperature range ambient -40 +85 oc operating temperature range case +100 oc storage temperature range -40 +125 oc cooling free air convection humidity rh, non-condensing 95 % physical case size 1.25 x 0.80 x 0.40 inches (31.8 x 20.3 x 10.2 mm) case material copper with nickel coating (ul94v-0) weight 0.60 oz (17g) reliability speci? cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25oc, gnd benign 1.0 mhours absolute maximum ratings parameter conditions min. typ. max. units input voltage surge (1 sec) 12 vdc input -0.7 25.0 vdc 24 vdc input -0.7 50.0 48 vdc input -0.7 100.0 lead temperature 1.5 mm from case for 10 sec 260 oc caution: exceeding absolute maximum ratings may damage the module. these are not continuous operating ratings.
model selection guide mechanical dimensions mechanical notes: all dimensions are typical in inch es (mm) tolerance x.xx = ?.02 (?.50) micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 ? tel: (781) 344-8226 ? fax: (781) 344-8481 ? e-mail: sales@micropowerdirect.com www.micropowerdirect.com derating curve pin single dual 2- v in -v in 3- v in -v in 9 no pin common 11 nc -v out 14 +v out +v out 16 -v out common 22 +v in +v in 23 +v in +v in nc: no connection pin connections model number input output over voltage protection (vdc) max capacitive load (f max) ef? ciency (%, typ) fuse rating slow-blow (ma) voltage (vdc) current (ma) voltage (vdc) current (ma, max) current (ma, min) nominal range full-load no-load ma1012s-02rw 12 9.0 - 18.0 791 10 2.5 3,000 0.0 3.9 2,200 81 2,500 ma1012s-03rw 12 9.0 - 18.0 1,006 10 3.3 3,000 0.0 3.9 2,200 84 2,500 ma1012s-05rw 12 9.0 - 18.0 992 10 5.0 2,000 0.0 6.2 2,200 86 2,500 ma1012s-12rw 12 9.0 - 18.0 980 10 12.0 833 0.0 15.0 820 87 2,500 ma1012s-15rw 12 9.0 - 18.0 958 10 15.0 667 0.0 18.0 470 89 2,500 ma1012d-12rw 12 9.0 - 18.0 980 10 12.0 416 0.0 15.0 220 87 2,500 ma1012d-15rw 12 9.0 - 18.0 969 10 15.0 333 0.0 18.0 150 88 2,500 ma1024s-02rw 24 9.0 - 18.0 381 10 2.5 3,000 0.0 3.9 2,200 84 1,200 ma1024s-03rw 24 9.0 - 18.0 497 10 3.3 3,000 0.0 3.9 2,200 85 1,200 ma1024s-05rw 24 18.0 - 36.0 479 10 5.0 2,000 0.0 6.2 2,200 89 1,200 ma1024s-12rw 24 18.0 - 36.0 485 10 12.0 833 0.0 15.0 820 88 1,200 ma1024s-15rw 24 18.0 - 36.0 485 10 15.0 667 0.0 18.0 470 88 1,200 ma1024d-12rw 24 18.0 - 36.0 485 10 12.0 416 0.0 15.0 220 88 1,200 ma1024d-15rw 24 18.0 - 36.0 474 10 15.0 333 0.0 18.0 150 90 1,200 ma1048s-02rw 48 9.0 - 18.0 191 10 2.5 3,000 0.0 3.9 2,200 84 750 ma1048s-03rw 48 36.0 - 75.0 249 10 3.3 3,000 0.0 3.9 2,200 85 750 ma1048s-05rw 48 36.0 - 75.0 242 10 5.0 2,000 0.0 6.2 2,200 88 750 ma1048s-12rw 48 36.0 - 75.0 245 10 12.0 833 0.0 15.0 820 87 750 ma1048s-15rw 48 36.0 - 75.0 242 10 15.0 667 0.0 18.0 470 88 750 ma1048d-12rw 48 36.0 - 75.0 245 10 12.0 416 0.0 15.0 220 87 750 ma1048d-15rw 48 36.0 - 75.0 245 10 15.0 333 0.0 18.0 150 87 750 notes: 1. load regulation is speci ed for a load change of 0% to 100%. load regulation for 3.3v output models is 1.0% max for a load change of 0% to 100%. 2. when measuring cross regulation, the load on one output is varied from 25% to 100% while the other output is held at 100%. 3. when measuring output ripple, it is recommended that an external 1.0 f ceramic capacitor be placed from the +v out pin to the -v out pin for single output units and from each output to common for dual output units. for noise sensitive applications, the use of 3.3 f capacitors will reduce the output ripple. 4. to help meet conducted emissions requirements, the pi lter components (c 1 , & l 1 ) in the diagram below should be used. these components should be mounted as close to the module as possible. to meet the requirements of en 61000-4-4 and en 61000-4-5, an external lter capacitor (c 2 in the diagram below) is required. 5. operation at no-load will not damage these units. however, they may not meet all speci cations. 6. dual output units may be connected to provide a 24 vdc or 30 vdc output. to do this, connect the load across the positive (+v out ) and negative (-v out ) outputs and oat the output common. 7. it is recommended that a fuse be used on the input of a power supply for protection. see the table above for the correct rating. recommended input components


▲Up To Search▲   

 
Price & Availability of MA1012D12RW

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X